Experimental study of a new hydrocarbon mixture for domestic re-frigerator to replace R134A
Abstract
In a domestic refrigerator with 4.49cc displacement compressors, the performance of R290 (48 by mass percent) and R600a (52 by mass percent) was examined experimentally. In our research, we employed a 210-litre refrigerator designed to run on R12 with a longer capillary. The amount of energy utilized and the pressure and temperature at crucial locations on the various refrigerated compartments and refrigerator circuits are all monitored. With R290/R600a, we performed a scroll-down test and ice-making test. According to our findings, R290/R600a are the best contenders for replacing R134a in terms of energy conservation. Because the amount of refrigerant utilized is so small, the flammability factor can be overlooked.
Downloads
References
Mohammad Salman, Rajendran Prabakaran, Poongavanam Ganesh Kumar, Dongchan Lee, Sung Chul Kim, Saturation flow boiling characteristics of R290 (propane) inside a brazed plate heat exchanger with offset strip fins, International Journal of Heat and Mass Transfer, Volume 202,2023,123778,ISSN 0017-9310,https://doi.org/10.1016/j.ijheatmasstransfer.2022.123778.
Mustafa Ozsipahi, Haluk Anil Kose, Husnu Kerpicci, Hasan Gunes, Experimental study of R290/R600a mixtures in vapor compression refrigeration system, International Journal of Refrigeration, Volume 133, 2022, Pages 247-258, ISSN 0140-7007, https://doi.org/10.1016/j.ijrefrig.2021.10.004.
Wongwises, S. and Chimers, N. (2005). Experimental study of hydrocarbon mixtures to replace HFC-134a in a domestic refrigerator. Energy conversion and management.46, 85-100. DOI: 10.1016/j.enconman.2004.02.011
Parashurama, S., Ramesha, D.K. & Govinde gowda, M.S. (2019). Screening of HFCs and Fluroethers as Alternatives to R134a Using SRK EoS. J.Inst.Eng.India, Ser.C. https://doi.org/10.1007/s40032-019-00501-5.
Parashurama, S (2019). Experimental Investigation of the Use of Propane for Domestic Refrigerator with Lower Displacement Compressor, International Journal of Heat and Technology. 37, 985-990. DOI: 10.18280/ijht.370407.
Anjappa S B, D.R.Partha Sarathi, Y.Srinath, N.Venkatramanareddy, “Solar Vaccine Refrigerator by using Phase Change Material”,(IJEAT) ISSN: 2249-8958 (Online), Volume-8 Issue-5, June 2019.
Parashurama, S., Ramesha, D.K. & Govinde gowda M.S.(2018). Development of alternative binary mixtures to replace hfc 134a in domestic refrigerator. Chemical Engineering Transactions. 71, 1399-1404. DOI: 10.3303/CET1871234
Data Acquisition Users Guide, ADAM4000 Series User’s manual
Copyright (c) 2024 ITEGAM-JETIA
This work is licensed under a Creative Commons Attribution 4.0 International License.